Product Description

Features:

  • Multiple-Echo for reliable, accurate through coating measurements
  • Large bright color LCD screen with automatic LCD back light
  • Min / max measurement limit functions with visual and vibrate alert
  • Extremely rugged enclosure - shock and impact to MIL STD 810G
  • Environment sealing to IP67 - MIL STD810G
  • Deep-coat mode, measures through coatings up to 20 mm (¾") thick
  • Cygnus echo-strength bars assist thickness measurements
  • TPE over molded enclosure
  • Buttons designed for minimum of 100,000 depressions
  • Fully sealed battery compartment (contains any leaking battery fluids)
  • Multiple-Echo Measuring Mode
    • Measures remaining metal thickness of corroded and coated structures
    • All measurements are error checked using 3 return echoes to give repeatable, reliable results
    • Accepted by all major classification societies
    • Echo strength indicator to aid measurement

Cygnus 4 CYG-050-4000-S2C General Purpose Multiple-Echo Ultrasonic Thickness Gauge includes:

  • (1) Padded Carry Case
  • (1) S2C Single Crystal 2.25 MHz x 13 mm (1/2”) Diameter Probe
  • (3) AA Batteries
  • (1) Adjustable Neck Strap and Loops
  • (1) Wrist Strap
  • (1) Accessory Pouch
  • Spare membranes
  • (1) Surface and Membrane Couplant
  • (1) Steel Test Block
  • Operation Manual

Specifications:

  • Materials: Sound velocities between 2000 m/s - 9000 m/s (0.079 in/ms - 0.35 in/ms) - covers virtually all common engineering materials
  • Accuracy: ±0.1 mm (±0.004”) or 0.1% of thickness measurement, whichever is greatest, when calibrated in accordance with Cygnus Instruments calibration procedure
  • Resolution: 0.1 mm or 0.05 mm (0.005" or 0.002")
  • Probes:
    • Single crystal probes:
    • 6 mm (¼”) - 5.0 MHz (S5A)
    • 13 mm (½”) - 2.25 MHz (S2C (standard)), 3.5 MHz (S3C) or 5.0 MHz (S5C)
    • 19 mm (¾”) - 2.25 MHz (S2D)
  • Measurement Range in Steel:
    • Single crystal probes:
    • 3 mm - 250 mm (0.120" - 10.00") with 2.25 MHz probe (S2C/D)
    • 2 mm - 150 mm (0.080" - 6.000") with 3.5 MHz probe (S3C)
    • 1 mm - 50 mm (0.040" - 2.000") with 5.0 MHz probe (S5C/A)
  • Connector: 1 x Lemo 1
  • Power: 3 x AA batteries
  • Battery Life: 10 hours minimum
  • Electronics: Dual channel pulser
  • Display: 2.4" quarter VGA LCD
  • Size: 5.20 in. x 3.23 in. x 1.34 in. (132 mm x 82 mm x 34 mm)
  • Weight: 300 grams (10.58 oz) including batteries
  • Operating Temperature: -14°C to 122°C (10°C to 50°C)
  • Environmental Rating
    • IP67
    • MIL STD 810G Method 501.6 (high temp +55°C)
    • MIL STD 810G Method 502.6 (low temp -20°C)
    • MIL STD 810G Method 507.6 (humidity 95%)
    • MIL STD 810G Method 512.6 (immersion - 1 metre for 30 mins)
  • Shock and Impact
    • MIL STD 810G Method 514.7 (vibration - 1 hour each axis) )
    • MIL STD 810G Method 516.7 (shock 20g - 11ms half sine shock pulse, 40g 11ms in each axis) )
    • MIL STD 810G Method 516.7 (26 drops - transit drop 1.22 m) )
  • Compliance: CE, British Standard BS EN 15317:2013 (Specification for the characterization and verification of ultrasonic thickness measuring equipment)
  • Environmental: RoHS, WEEE compliant
  • Warranty: 3 years on gauge and 6 months on probe

Product Reviews

Write Review

This product hasn't received any reviews yet. Be the first to review this product!

  • Cygnus echo-strength bars assist thickness measurements
  • TPE over molded enclosure
  • Buttons designed for minimum of 100,000 depressions
  • Fully sealed battery compartment (contains any leaking battery fluids)
  • Multiple-Echo Measuring Mode
    • Measures remaining metal thickness of corroded and coated structures
    • All measurements are error checked using 3 return echoes to give repeatable, reliable results
    • Accepted by all major classification societies
    • Echo strength indicator to aid measurement

    Cygnus 4 CYG-050-4000-S2C General Purpose Multiple-Echo Ultrasonic Thickness Gauge includes:

    • (1) Padded Carry Case
    • (1) S2C Single Crystal 2.25 MHz x 13 mm (1/2”) Diameter Probe
    • (3) AA Batteries
    • (1) Adjustable Neck Strap and Loops
    • (1) Wrist Strap
    • (1) Accessory Pouch
    • Spare membranes
    • (1) Surface and Membrane Couplant
    • (1) Steel Test Block
    • Operation Manual

    Specifications:

    • Materials: Sound velocities between 2000 m/s - 9000 m/s (0.079 in/ms - 0.35 in/ms) - covers virtually all common engineering materials
    • Accuracy: ±0.1 mm (±0.004”) or 0.1% of thickness measurement, whichever is greatest, when calibrated in accordance with Cygnus Instruments calibration procedure
    • Resolution: 0.1 mm or 0.05 mm (0.005" or 0.002")
    • Probes:
      • Single crystal probes:
      • 6 mm (¼”) - 5.0 MHz (S5A)
      • 13 mm (½”) - 2.25 MHz (S2C (standard)), 3.5 MHz (S3C) or 5.0 MHz (S5C)
      • 19 mm (¾”) - 2.25 MHz (S2D)
    • Measurement Range in Steel:
      • Single crystal probes:
      • 3 mm - 250 mm (0.120" - 10.00") with 2.25 MHz probe (S2C/D)
      • 2 mm - 150 mm (0.080" - 6.000") with 3.5 MHz probe (S3C)
      • 1 mm - 50 mm (0.040" - 2.000") with 5.0 MHz probe (S5C/A)
    • Connector: 1 x Lemo 1
    • Power: 3 x AA batteries
    • Battery Life: 10 hours minimum
    • Electronics: Dual channel pulser
    • Display: 2.4" quarter VGA LCD
    • Size: 5.20 in. x 3.23 in. x 1.34 in. (132 mm x 82 mm x 34 mm)
    • Weight: 300 grams (10.58 oz) including batteries
    • Operating Temperature: -14°C to 122°C (10°C to 50°C)
    • Environmental Rating
      • IP67
      • MIL STD 810G Method 501.6 (high temp +55°C)
      • MIL STD 810G Method 502.6 (low temp -20°C)
      • MIL STD 810G Method 507.6 (humidity 95%)
      • MIL STD 810G Method 512.6 (immersion - 1 metre for 30 mins)
    • Shock and Impact
      • MIL STD 810G Method 514.7 (vibration - 1 hour each axis) )
      • MIL STD 810G Method 516.7 (shock 20g - 11ms half sine shock pulse, 40g 11ms in each axis) )
      • MIL STD 810G Method 516.7 (26 drops - transit drop 1.22 m) )
    • Compliance: CE, British Standard BS EN 15317:2013 (Specification for the characterization and verification of ultrasonic thickness measuring equipment)
    • Environmental: RoHS, WEEE compliant
    • Warranty: 3 years on gauge and 6 months on probe
    ">