ElektroPhysik MiniTest 735 F15 Description
p>Innovative and versatile, this gauge facilitates non-destructive coating measurement of non-magnetic coatings on ferromagnetic substrates and insulating coatings on conductive substrates. Additionally, it features a measuring speed setting option allowing adjustments to changing requirements for utmost efficiency and optimum productivity: taking many readings in a short time with medium precision or taking only a few with increased accuracy.
Features
- Correct readings with the interference-free measurement with precise evaluation through SIDSP®
- External sensor
- Automatic substrate identification with FN sensors (sold separately)
- Efficient temperature compensation
- High precision characteristic curves achieved during the manufacturing process by calibrating up to 50 calibration points
- Large memory capacity for storing up to 10,000 readings
- Readings and statistical values can be called-up individually
- Monitoring of limits, user-adjustable offset, and correction value for rough substrate materials
- Continuous measuring mode
- Easy menu-guided operation, 20 menu languages available
- Measurement data can be transferred by Bluetooth or USB to PCs, tablets, or smart phones
- Future-proof through downloadable sensor and gauge software updates
- Audible and visual (red and green LED) alarms
- Large, easy-to-read backlit graphics display
- Display orientation can rotate 180° so readings will never be upside down
- Factory set, zero, 2-point, 3-point, and roughness calibration
- SSPC-PA2, ISO, Swedish (SS 18 41 60), Australian (AS 3894.3), ISO 19840 and ASTM D 7091 (formerly D 1186 and D 1400)
SIDSP sensors
SIDSP® stands for Sensor-Integrated Digital Signal Processing: this technology completely processes signals into digital form inside the sensor at the time and point of measurement. Unlike conventional techniques, these sensors create and control the excitation signals for the sensor head inside the sensor. The return signals are digitally converted and processed at 32 bits of accuracy to give an entire coating thickness value.
This technique uses highly sophisticated digital signal processing methods known from modern telecommunication technologies (mobile phone networks), such as digital filters, base band converting, averaging, stochastic analysis, etc., and enables users to achieve a signal quality and precision unmatched by analog signal processing and digitally transmit the thickness value via the sensor cable to the display unit. This technology offers decisive advantages and improvements compared to the commonly used analog sensors. Moreover, these sensors guarantee the following:
- High stability of measuring signals
- The characteristic curves feature high accuracy
- Provide excellent adaptability
- N and FN sensors compensate for substrate conductivity (sold separately)
- Hhighly insensitive to changes in temperature
- Wear-resistant
- Future-oriented solutions
Applications
- Automotive
- Ship building
- Steel and bridge construction
- Electroplating
ElektroPhysik MiniTest 735 F15 Specifications
Sensor | Measuring principle: Magnetic-induction Type: D Measuring range: 0 to 15 mm Uncertainty (of reading) referring to multipoint calibration: ±(5 µm + 0.75%) Minimum measuring spot: ø25 mm |
Memory | Number of memories: 10, user-definable memory arrangement according to batches Total memory capacity: Maximum 10,000 Memory batches: Includes readings, a defined calibration mode, parameters, and statistics calculated from batch readings |
Statistical Evaluation | Number of readings, minimum, maximum, mean value, standard deviation, coefficient of variation |
Single Reading Statistics | Block value statistics (norm-conforming/user-configurable), stored readings, and statistical values can be called separately, print-out readings and statistics on a data printer (sold separately), transfer of readings and statistics to a PC |
Calibration Modes | Factory calibration, zero-point, 2-points, 3-point calibration, calibration method "rough", user-adjustable off-set value, user-adjustable correction value for substrate roughness |
International Calibration Procedures | ISO, SSPC, "Swedish", "Australian" |
Measuring Units | Metric: µm, mm, cm Imperial: mils, inch, thousands switchable |
Measuring Rate/Accuracy | User adjustable to standard, quick, high precision |
Thickness Identification | Continuous mode for quick identification of changes in thickness |
Display | Large graphical display, backlit, 180° rotatable |
Menu | User-friendly, 25 languages |
Software | Sensor and gauge software updates available via download |
Data Interfaces | Bluetooth 4.0, Bluetooth Smart, Mini-USB |
Power Supply | 2 x AA (Mignon cells), rechargeable NiMH Accu batteries type AA/HR6 (as an option) |
Automatic Switch-Off | Battery saving mode with adjustable switch-off mode |
Temperature | Operating: 50 to 140°F (-10 to 60°C) Storage: -4 to 158°F (-20 to 70°C) |
Protection | IP40 |
Norms and Standards | DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, 19840, ASTM B 244, B 499, D7091, E 376, AS 3894.3, SS 1841 60, SSPC-PA 2 |
Dimensions | 6.18 x 2.97 x 1.93" (157 x 75.5 x 49 mm) |
Weight | Approximately 7.4 oz (210 g) |
ElektroPhysik MiniTest 735 F15
What's included with the ElektroPhysik MiniTest 735 F15
ul>
- Coating Thickness Gauge
- Manufacturer's Certificate
- SIDSP Sensor
- Calibration Set with Calibration Standards and Zero Reference Plate(s)
- Shoulder Bag with Belt Clip
- 2 x Type AA Mignon Batteries
- Operating Instructions in German/English/French/Spanish on CD
- MSoft 7 Basic Data Transfer Software
- One-Year Warranty