Hioki CT6876A 1000A DC to 1.5 MHz Current Sensor 3m
Hioki's pass-through type AC/DC current sensors can be connected directly to Hioki Power Analyzers and Memory HiCorders. Also, it can be connected to Power Meters, Oscilloscopes, DMMs, etc. by using an optional sensor unit.
The CT6876A has a frequency bandwidth of DC to 1.5 MHz (Model CT6876A-1 is DC to 1.2 MHz) and a rated current of 1000 A. It is used for R&D, quality evaluation, manufacturing, and maintenance in markets such as wireless charging systems, inverter motors for industrial equipment, power conditioners for PV, and quick charging facilities for EVs.
Key Features
- High accuracy (amplitude): [DC]±0.048 %, [50 Hz/60 Hz]±0.048 %
High accuracy (phase): [50 Hz/60 Hz]±0.08° - The ideal current sensor for measuring large 1000 A currents in EV, HEV, and PHEV
- Strengthened shield improves noise resistance to accurately measure current buried in noise
- Flat frequency characteristics and CMRR performance to achieve high accuracy measurement
- More enhanced environmental resistance performance than ever before with operating temperature range of -40 to 85°C
- Good frequency characteristics over wide band of DC to 1.5 MHz (amplitude) and DC to 1 MHz (phase)
- Ideal for advanced fields such as photovoltaics and fuel cells to evaluate the charge / discharge of batteries and secondary side of inverters
- Connect with oscilloscopes or Hioki Memory HiCorders (using SENSOR UNIT) to monitor waveforms
Rated current | 1000 A AC/DC | |||||
---|---|---|---|---|---|---|
Max. allowable input | Within the derating range, up to ±1800 Apeak (design value) allowed at 40°C or less for 20 ms or less | |||||
Frequency bandwidth | Amplitude: DC to 1.5 MHz (CT6876A), DC to 1.2 MHz (CT6876A-1) Phase: DC to 1 MHz | |||||
Basic accuracy | (DC, 45 Hz ≤ f ≤ 66 Hz) Amplitude: ±0.04 % rdg. ±0.008 % f.s., Phase: ±0.08° | |||||
Output voltage rate | 2 mV / A rated (This device outputs AC+DC voltage via the Sensor Unit) | |||||
Max. rated voltage to earth | 1000 V AC/DC (50/60 Hz, CAT III ) | |||||
Core diameter | φ 36 mm (1.42 in) | |||||
Operating temperature, humidity | -40°C to +85°C (-40°F to 185°F), 80% RH or less (with no condensation) | |||||
Power supply | Power suppled via the Power Analyzer PW8001, PW6001, PW3390, or Sensor Unit CT9555, CT9556, CT9557 | |||||
Max. rated power | 7.5 VA max. (at 1000 A/55 Hz) | |||||
Dimensions and mass | 160 mm (6.30 in)W × 112 mm (4.41 in)H × 50 mm (1.97 in)D, CT6876A: 950 g (33.5 oz), cable length 3 m (9.84 ft), CT6876A-1: 1250 g (44.1 oz), cable length 10 m (32.81 ft) | |||||
Included accessories | Instruction Manual ×1, Mark bands ×6, Operating Precautions ×1 |
Compatible models
Compatible models | CT6876A | |||||
---|---|---|---|---|---|---|
Power Analyzer PW8001, PW6001, PW3390 | Ok | |||||
Power Analyzer 3390 | Attention (Requires CT9901) CT ratio 2 | |||||
Power HiTester 3193 series | Attention (Requires CT9901) CT ratio 2 | |||||
Current Unit 8971 | Attention (Requires the 9318, CT9901) CT ratio 2 |