Megger 1013-356 DPM1000 power clamp meter
$535.00
- Brand
- Megger
- SKU:
- 1013-356
- Availability:
- In Stock
- Model No:
- DPM1000
Megger DPM1000 Description
Ideally suited to measure DC, AC, pulsed and mixed currents up to 1000 A, the power clamp meter comes complete with test leads and thermocouple probe. By either clamping the jaws around the appropriate conductor, using the supplied test leads, or working with a combination of both techniques, power measurements are made easy with the ergonomic and easy-to-use unit. With auto-ranging and three-phase rotation indication, this meter detects all power-related parameters, including energy consumption, frequency, total harmonic distortion, distortion factor, and capacitance.
Features
- 10000 count digital display
- Active backlight with large scale display
- VoltSeek (non-contact voltage detection)
- Analog bar graph
- True RMS reading on AC and AC+DC mode
- Memory save/load (up to 1000 records)
- Data logger (up to 9999 sample values)
- Bluetooth communication
- Torch turns on when clamp jaws open
- Auto selecting 1000 A AC/DC current measurement
- Auto selecting 1000 V AC/DC voltage measurement
- 100 kΩ resistance measurement
- Continuity beeper
- Frequency counter
- Power and power factor measurement
- Total harmonics distortion
- Harmonics measurement: 1st to 25th
- Capacitance capability
- °F/°C temperature function
- Inrush current
- DCA auto-zeroing button
- Peak hold
- Maximum/Minimum hold
- Smart data hold
- Phase rotation
- High frequency noise rejection filter
- Auto power off (APO)
- CAT IV 600 V/CAT III 1000 V safety standard
Megger DPM1000 Specifications
ACA | Range: 100 to 1000 A Resolution: 0.01 A Basic accuracy: ±(1.5% +5 d) at 50 to 500 Hz Conversion type: AC and DC True RMS |
ACV | Range: 100 to ~1000 V Resolution: 0.01 V Basic accuracy: ±(1.5% +5 d) at 50 to ~500 Hz Input impedance: 3.5 MΩ Overload protection: 1000 V rms |
DCA | Range: 100 to 1000 A Resolution: 0.0 1 A Basic Accuracy: ±(1.5 % +5 d) |
DCV | Range: 100 to ~1000 V Resolution: 0.01 V Basic accuracy: ±(0.7% +2 d) Input impedance: 3.5 MΩ Overload protection: 1000 V rms |
AC + DCV | Range: 100 to ~1000 V Resolution: 0.01 V Basic accuracy: ±(1.7% +7 d) Input impedance: 3.5 MΩ Overload protection: 1000 V rms |
Harmonics | Range: 0.1 to ~100% Resolution: 0.1% Basic accuracy: ±(5.0% +10 d) for order 1-12 ±(10.0% +10 d) for order 13-25 |
Resistance | Range: 1 to 100 kΩ Resolution: 0.01 Ω Basic accuracy: ±(1.0% + 5 dgt) Overload protection: 1000 V rms |
Continuity Beeper | <30 Ω, 2 kHz tone buzzer |
Diode Test | Open circuit voltage: ±1.8 V maximum |
Capacitance | Range: 4 to 4000 μF Resolution: 1 nF Basic accuracy: ± (1.9% +8 d) Overload protection: 1000 V rms |
Frequency Counter | Range: 20.00 Hz to ~10.00 kHz Resolution: 0.01 Hz Accuracy: ±0.5% +3 d |
Temperature | Range: -58 to ~1832°F (14.4 to ~1000°C) Resolution: 32.2°F (0.1°C) Accuracy ±1.0% +37.4°F (3°C) Overload protection: 1000 V rms Operating: 32 to ~122°F (0 to ~50°C), ≤80% RH Storage: 14 to ~122°F (-10 to ~50°C) Coefficient 0.2 x (Spec. Acc)/°C, <64.4°C or >82.4°C |
Maximum Conductor Size | 1.5" (40 mm) |
Maximum Busbar Size | 2.4 x 0.4" (61 x 12 mm) |
Dimensions | 4.05 x 10.1 x 2.1" (103 x 258 x 55 mm) |
Weight | 1.3 lbs (600 g) |
Applications
- Power electronics
- Power engineering