Mitutoyo 264-155A QM-DATA200 STAND TYPE
- Brand
- Mitutoyo
- SKU:
- 264-155A
- Availability:
- In Stock
Mitutoyo 264-155A Offers
Suitable for production sites, this stand-mount type data processing unit features powerful 2-D coordinate measurement capabilities and improves operator productivity, minimizes errors, and saves measurement time and production cost. In addition, this data processing unit is a geometric readout/analysis unit for optical instruments like profile projectors.
Features
- Various graphic displays on the large colored LCD screen for easy measurement operations
- One-key operation for combined measurements that are often used (circle-circle distance, etc.)
- The AI measurement function (automatic identification of measuring item) eliminates switching between the measurement command keys
- Equipped with the measurement procedure teaching function and the measuring position navigation in repeat mode
- The user menu function allows user to register measurement commands or part programs to create his own menu
- Measurement result output to "MS-Excel" in spreadsheet (CSV) format
- The measurement procedure and measurement result can be saved, using a USB drive
- Reduction of measurement time
- Measurements that anyone can perform, and with less variation
- Quality control based on data management system
- Three screens selectable according to purpose: Measurement procedure navigation screen, enlarged counter display, and measurement result screen in the graphic display is selectable according to your purpose
- Experience measurement with this data processing unit: The comprehensive key panels of this data processing unit make it easy for any operator to use and simple operations help you concentrate on measurements
Intuitive panel design
This data processing unit employs geometry keys to accelerate the measurement process. The probing routine of standard geometric features and combinations are designed with geometry keys on the front panel. Click the key you need and capture features to complete the measurement quickly and accurately. This improves operator productivity, reduce errors, and saves operation time and cost
Graphic display
Measurement information and data are visualized on the back-lit colored LCD with graphical interfaces. The geometric feature selected is displayed with the probing navigator. The measurements map and blink indication show the probing points and sequences. This improves operation accuracy and reduces errors and time.
Promotes smart factory by collecting and managing measurement data
Collects data in the inspection process swiftly and accurately, and increases a company's competitiveness based on detailed data analysis. Optical data-processing system is what supports such a system configuration.
Applications
- Production sites
Data processing unit with easy operation
Easy operation
A color LCD panel with high visibility is adopted for an interactive system that guides the operator according to screen instructions. This allows easy operation even for first-time users of this data processing unit. This data processing unit is intended for production sites in various environments, adopting high durability sheet switches and proprietary electronic components.
User menu
In the user menu, the "Measurement command," "User macro," and "Part program" can be registered. (Up to 3 menus.) You can register a "Part program" for each workpiece to measure, and customize an original system to best suit the operator's needs. The registered user menus can be saved on a USB storage device, enabling a backup or sharing on multiple data processing units.
Efficiency
The coordinate entry format function (NP measurement)
In a measurement using the coordinate entry format, the coordinates calculated from the measurement data (coordinates of the center of a circle, etc.) are applied to data entry as one measuring point. For example, measurement of the pitch of a rectangular hole can be executed simply by selecting the (PITCH MEASUREMENT) key and (RECTANGULAR HOLE CENTER) in the coordinate entry format. Without calling up and re-calculating measurement result, (COORDINATE ENTRY FORMAT) can use with pattern and basic measurements.
Types of coordinate entry formats
- Directly entered points: Use the point that has been entered as a measuring point
- Center of ellipse: Use the center of the ellipse as a measuring point
- Midpoint between the two: Use the midpoint between the two points as a measuring point
- Center of rectangular hole: Use the center of the rectangular hole as a measuring point
- Center of circle (three points): Use the center of the circle whose 3 points have been entered as a measuring point
- Center of slotted hole: Use the center of the slotted hole as a measuring point
- Center of circle (four points): Use the center of the circle whose 4 points have been entered as a measuring point
- Intersection of two straight lines: Use the intersection of the two straight lines as a measuring point
Manual operation functions for greater measuring efficiency
Navigation of measuring position
When using the repeat function to execute a measurement procedure (part program) created with the teaching function*, the repeat function guides the operator to the next measuring point. The number of repeat times for a part program can be specified.
Mitutoyo 264-155A Specifications
Measured Valued Units | Length: mm/in Angle: degree/degree minute second (selectable) |
Resolution | 0.1 µm |
Program Functions | Part program creation, execution, editing |
Statistical Processing | Number of data, maximum value, minimum value, mean value, standard deviation, range, histogram, statistics on a measuring function basis (by command) |
Element | Memory: Maximum of 1000 elements Recall: Point, line, circle, distance, ellipse, rectangular hole, slotted hole, intersection and intersecting angle Key-in: Point, line, circle |
Display System | Color TFT LCD (with LED backlight) |
Edge Sensor Position Compensation | Supported (projector) |
Input/Output | X, Y, Z: Maximum of three linear scale inputs RS-232C 1: For connecting to external PC RS-232C 2: For connecting to counter of measuring instrument OPTOEYE: For inputting edge signal from OPTOEYE (OPTOEYE M2) |
Measurement Result File Output | RS-232C output (CSV format, MUX-10 format) |
Power | 120 V |
Maximum Power Consumption | 17 W |
Display Languages (Selectable) | Japanese/English/German/French/Italian/Spanish/Portuguese/Czech/Simplified Chinese/Traditional Chinese/Korean/Turkish/Swedish/Polish/Dutch/Hungarian |
Dimensions | Approximately 10.24 x 9.53 x 12.2" (260 × 242 × 310 mm), including the stand |
Weight | Approximately 6.4 lbs (2.9 kg) |
What's included with the Mitutoyo 264-155A
- Mitutoyo QM-Data200 Stand-Mount Type 2D Data Processing Unit, 120 V