MSA 10106621 Kit:Replcmnt,Main Bd W/Batt Pk,Altair4X
- Brand
- MSA
- SKU:
- 10106621
- UPC:
- 4.03E+12
- Availability:
- DISCONTINUED, NO REPLACEMENT, NO STOCK
Description
Features
-
Dependable multigas detector tests for LEL, oxygen, carbon monoxide and hydrogen sulfide
-
Economical construction saves users more than 50% on calibration gas, replacement sensors and maintenance
-
Four-year sensor life means detector lasts 60% longer than the industry average
-
Unit uses 50% less calibration gas per minute than the average detectors within the industry
-
Two-tox CO/h4S sensor removes practically all cross-channel interference
-
Large buttons and high-contrast screen make operation easy in low-light conditions
-
Ribbed rubber housing provides secure grip and high durability
-
Unit features 95+ db alarm and ultra-bright LEDs
-
Exclusive end-of-sensor warning cautions user when unit's sensor needs to be changed
-
MotionAlert option tells others that user has become immobile
-
InstantAlert provides manual alarm to alert others of a dangerous situation
Technical Information
Altair® 4x Technical Specifications
Drop test 20 feet
Housing Rugged rubberized armor
Weight 7.9 oz
Dimensions (L x W x D) 4.4 x 3.0 x 1.31
Audible alarm 95 dB at 1 ft
Visual alarm 4 ultra-bright LEDs on top and bottom
Vibrating alarm Standard
MotionAlert InstantAlert Optional
Display High Contrast LCD
Backlight Adjustable time-out
Battery Rechargeable li-polymer
Run time 24 hours @ room temperature
Charging time 4 hrs
Operating temperature range 20ºC to + 50ºC
Short Period Operation -??40°C to +60°C
Humidity 15 90% RH non-condensing
Ingress protection IP67
Data log (Adjustable) 50 hour minimum
Event log Standard 500 events
Standard warranty 3 years
Extended warranty Optional 1 year
Certifications
U.S./Canada:
- CSA Class I, Div.1, Groups A, B, C, D Tamb = 40 °C to +54 °C
- CAN/CSA C22.2 152; ISA 12.13.01-2000
- ETL Class II, Div.1, Groups E, F and G Class III, Div.1 T amb = ??40°C to +54°C; T4
- ATEX: II 1G Ex ia IIC T4, 40°C to +60 °C, IP67 (Zone 0 with no combustible sensor installed) II 2G Ex ia d IIC T4, ??40°C to +60°C, IP67 (Zone 1 with combustible sensor installed)
- IEC: Ex ia IIC T4, ??40°C to +60°C (Zone 0 with no combustible sensor installed) Ex ia d IIC T4, ??40°C to +60°C (Zone 1 with combustible sensor installed)
Australia/New Zealand:
- Ex ia s IIC T4, 40°C to +60°C, IP67 (Zone 0)
X Cell® Sensor Technical Specifications
LEL
Gas Range:0-100%
Resolution:1%
O2
Gas Range:0-30% vol
Resolution:0.1% vol
CO
Gas Range: 0-1999ppm
Resolution:1 ppm
h4S
Gas Range:0-200ppm
Resolution:1 ppm