MSA 10152629 Gas,875L,1.45%Ch4,15%O2,60Ppmco,20Ppmh2S
- Brand
- MSA
- SKU:
- 10152629
- UPC:
- 6.42E+11
- Availability:
- none
DescriptionThe ALTAIR 4X Multigas Detector surpasses industry standards in several crucial areas. Its four-year sensor life is 60% longer than the industry average, while its 24-hour run time exceeds the industry average by 71%. This versatile portable detector is a perfect match for industries ranging from fire fighting to welding, and its digital sensor output makes it less likely to suffer from RF interference. The unit features exclusive MotionAlert, which lets others know if the user has become immobile, and InstantAlert, a manual alarm that alerts others of potentially dangerous situations. This rugged unit is designed to withstand a drop of up to 20 feet and uses less than half as much calibration gas as the industry average.
Features
Dependable multigas detector tests for LEL, oxygen, carbon monoxide and hydrogen sulfide
Economical construction saves users more than 50% on calibration gas, replacement sensors and maintenance
Four-year sensor life means detector lasts 60% longer than the industry average
Unit uses 50% less calibration gas per minute than the average detectors within the industry
Two-tox CO/h4S sensor removes practically all cross-channel interference
Large buttons and high-contrast screen make operation easy in low-light conditions
Ribbed rubber housing provides secure grip and high durability
Unit features 95+ db alarm and ultra-bright LEDs
Exclusive end-of-sensor warning cautions user when unit's sensor needs to be changed
MotionAlert option tells others that user has become immobile
InstantAlert provides manual alarm to alert others of a dangerous situation
Technical Information
Altair® 4x Technical Specifications
Drop test 20 feet
Housing Rugged rubberized armor
Weight 7.9 oz
Dimensions (L x W x D) 4.4 x 3.0 x 1.31
Audible alarm 95 dB at 1 ft
Visual alarm 4 ultra-bright LEDs on top and bottom
Vibrating alarm Standard
MotionAlert InstantAlert Optional
Display High Contrast LCD
Backlight Adjustable time-out
Battery Rechargeable li-polymer
Run time 24 hours @ room temperature
Charging time 4 hrs
Operating temperature range 20ºC to + 50ºC
Short Period Operation -40°C to +60°C
Humidity 15 90% RH non-condensing
Ingress protection IP67
Data log (Adjustable) 50 hour minimum
Event log Standard 500 events
Standard warranty 3 years
Extended warranty Optional 1 year
Certifications
U.S./Canada:
- CSA Class I, Div.1, Groups A, B, C, D Tamb = 40 °C to +54 °C
- CAN/CSA C22.2 152; ISA 12.13.01-2000
- ETL Class II, Div.1, Groups E, F and G Class III, Div.1 T amb = 40°C to +54°C; T4
- ATEX: II 1G Ex ia IIC T4, 40°C to +60 °C, IP67 (Zone 0 with no combustible sensor installed) II 2G Ex ia d IIC T4, 40°C to +60°C, IP67 (Zone 1 with combustible sensor installed)
- IEC: Ex ia IIC T4, 40°C to +60°C (Zone 0 with no combustible sensor installed) Ex ia d IIC T4, 40°C to +60°C (Zone 1 with combustible sensor installed)
Australia/New Zealand:
- Ex ia s IIC T4, 40°C to +60°C, IP67 (Zone 0)
X Cell® Sensor Technical Specifications
LEL
Gas Range:0-100%
Resolution:1%
O2
Gas Range:0-30% vol
Resolution:0.1% vol
CO
Gas Range: 0-1999ppm
Resolution:1 ppm
h4S
Gas Range:0-200ppm
Resolution:1 ppm