OAKTON WD-35412-00 CON 2700 Benchtop Meter with conductivity/probe, software, and probe stand
- Brand
- OAKTON
- SKU:
- WD-35412-00
- Availability:
- DISCONTINUED WITHOUT A REPLACEMENT, NO STOCK
Description
CON 2700 meter 4-cell, K=1 Conductivity/temp probe, electrode stand, and software
Measure Conductivity, total dissolved solids (TDS), salinity, resistivity, and temperature
Brilliant backlit display with dynamic stability indication Up to 500 point memory with date-time stamp for GLP Output data to printer or PC Accepts either 2-cell or 4-cell electrodes Features auto-standardization, auto-calibration, and autoranging Calibration due alarm with password protection for setup and calibration Measures salinity from 0.0 to 80 ppt and resistitivy from 2.000 ohms to 20.0 Mohms
The CON 2700 meter offers a new compact design that is over 40% smaller than other benchtop meters. The large display is easy to read even at a distance and features stability indication. All measurements include temperature display. The meter includes automatic or manual temperature compensation, temperature in °F or °C, and display Hold. A calibration due alarm function means no more out-dated calibrations. The water-resistant membrane keypad offers password protection for both set-up and calibration.
Multiple pH slopes and offset display enables quick, easy electrode diagnosis. The electrode holder can be mounted on either side of the meter. The convenient pull-out, quick-reference card keeps keypad functions at your fingertips.
Specification
RS-232 | Bi-directional RS-232 with software |
Measures | Conductivity, TDS, salinity, resistivity, and temperature (°F or °C) |
Conductivity Range | 0.050 uS/cm to 500.0 mS/cm |
Conductivity Resolution | 0.01 uS/0.1 uS; 0.001 uS/ 0.01 mS/0.1 mS |
Conductivity Accuracy | ±1% full scale |
Conductivity Calibration | Automatic (4 points); maximum 1 per range; manual (5 points); maximum 1 per range |
TDS Range | 0.050 ppm to 500 ppt @ 1.00 TDS factor |
TDS Resolution | 0.01 ppm/0.1 ppm; 0.001 ppt/ 0.01 ppt/0.1 ppt |
TDS Accuracy | ±1% full scale |
TDS Calibration | Up to 5 points |
Temperature Range | 0.0 to 100.0 °C / 32.0 to 212.0 °F |
Temperature Resolution | 0.1°C/ 0.1°F |
Temperature Accuracy | ±0.3 °C / ±0.5 °F |
Temperature Calibration | Offset 0.1°C increments up to ±5°C/±9°F |
Memory | Up to 500 data sets with time-date stamp for GLP |
Cell constant | 0.010 to 10,000 |
Temperature coefficient | Linear and pure; 0.000 to 10.000% |
Dimensions | 6 1/8" x 6 7/8" x 2 3/4" (15.5 x 17.5 x 6.9 cm) |