OAKTON WD-35431-00 PC 650 Meter / probe
$1,284.00
- Brand
- OAKTON
- SKU:
- WD-35431-00
- Availability:
- In Stock
Description
PC 650 Meter with probes
Two most common electrochemistry measurements in one convenient meter!
- Durable waterproof and dustproof design with IP67 rating - Even with no probes attached
- Push-button pH calibration at up to six points - Up to 15 buffer options with autobuffer recognition of USA, NIST, DIN, and PWB standards
- Large backlit graphic display - Multiline display with electrode status indicator, calibration data, and more
- User-settable "calibration due" alarm - Out-of-date or unperformed calibrations are now things of the past!
- Built-in real-time clock - Time-and-date stamping meets Good Laboratory Practice (GLP) standards
- Store up to 500 data sets - Infrared IrDA wireless technology makes PC downloading convenient and easy
- Set point alarms - Audible warning when readings are outside set points limit
- Research-grade accuracy - Resolution to 0.001 pH and accuracy to ±0.002 pH
- Electrode status indicator - Calibration data provides electrode diagnostic tool
- Password protection - Security for calibration and setup menus
Specification
| Range | PH | -2.000 to 20.000 pH |
| Ion | 0.001 to 19,900 ppm, molar, or mq/L | |
| mV | ±2000 mV | |
| Conductivity | 0 to 500.0 mS | |
| TDS | 0 to 500 ppt | |
| Salinity | 0 to 80 ppt | |
| Resistivity | 0 to 20.00 M? | |
| Temperature | -10.0 to 110.0°C (14.0 to 230.0°F), selectable | |
| Resolution | pH | 0.1/0.01/0.001 pH |
| Ion | 2 or 3 digits | |
| mV | 0.1 mV | |
| Conductivity | 0.05% full-scale | |
| Temperature | 0.1°C (0.1°F) | |
| Accuracy | pH | ±0.002 pH |
| Ion | ±0.5% full-scale (monovalent); 1% full-scale (divalent) | |
| mV | ±0.2 mV | |
| Conductivity | 1% full-scale | |
| Temperature | ±0.5°C (±0.9°F) | |
| Calibration | pH | Up to 6 buffer values (select from 4 sets): USA: 1.68,4.01,7.01,10.01,12.45; NIST: 1.68,4.01, 6.86, 9.18,12.45; DIN: 1.09, 2.06,4.65,6.79, 9.23,12.75; or custom buffers |
| Ion | Up to 6 points | |
| Conductivity | Manual up to 5 points (1 per range); automatic up to 4 points (84.0 µS/cm, 1413 µS/cm; 12.88 mS/cm, 111.8 mS/cm) | |
| Temperature | Offset 0.1°C (0.1°F) increments | |
| Memory | up to 500 sets with GLP date and time | |
| Output | infrared, IrDA | |
| Real-time clock | time-and-date stamp on calibration and stored data | |
| Temperature compensation | automatic or manual (selectable), from 0 to 100°C | |
| Ambient operating temperature | 0 to 50°C (32 to 122°F) | |
| Power | four 1.5 V AA batteries (included) or optional universal AC adapter, up to 200 hours continuous use | |
| Dimensions | Meter | 7½"L x 3¾"W x 2¼"H (19 x 9.5 x 5.7 cm) |
| Boxed | 91/8"L x 91/8"W x 2¾"H (23 x 23 x 7 cm) | |
| Weight | Meter | 1 lb (0.5 kg) |
| Boxed | 2. lb (0.9 kg) | |