RKI 35-3001A-01H 35-3001 for Hydrogen specific 100% LEL with transmitter
$1,925.00
- Brand
- RKI Instruments
- SKU:
- 35-3001A-01H
Description
Features
- Available in LEL, O22, H2S, CO, CO2, H2 (ppm or LEL)
- Multigas versions available with sensors in one enclosure
- Internal sample pump with 100' range
- Flowmeter and LED's for operational status
- Low flow indication
- NEMA 4X enclosure
- Operates on 24 V DC input
- Optional 4-20 mA output
Applications
- Petrochemical plants
- Refineries
- Water and wastewater treatment plants
- Pulp and paper mills
- Gas, telephone, and electric utilities
- Parking garages
- Manufacturing facilities
- Steel
- Automotive
- HVAC/R
Specification
| Target Gas and Detection Range | Hydrogen: 0 to 100% LEL |
| Input Power | 24 V DC nominal (18.5 V DC to 30 V DC) |
| Sampling Method | Sample-draw |
| Sample Flow | 3.0 SCFH typical, with no inlet or exhaust line |
| Flow to Sensor | 1.0 SCFH (nominal) |
| Low Flow Setpoint | 0.6 ±0.1 SCFH |
| Response Time | 90% in 30 seconds |
| Accuracy | ±5% of reading or ±2% LEL (whichever is greater) |
| Construction (Housing) | Fibreglass/polyester (NEMA 4X) |
| Dimensions | 8.5 x 6.5 x 4.25" (215.9 x 165.1 x 107.9 mm) |