RKI 72-1004-05 OX-600 oxygen monitor, 0-25%, battery operated (2 AA batteries) with 5 meter sensor cable installed
$945.00
- Brand
- RKI Instruments
- SKU:
- 72-1004-05
Description
Ideal for indoor oxygen detection, this oxygen monitor has a compact wall mount design.
Features
- Operates with or without a controller
- Tricolor visual alarm display: Green=Normal, Yellow=Alarm 1, Red=Alarm 2
- Large easy to read digital display
- Three power options: 115 V AC, 24 V DC, or two AA alkaline batteries
- Operates up to one year on one set of AA alkaline batteries
- Pressure compensation eliminates false alarms caused by pressure change
Applications
- Laboratories
- Cryogenic environments
- Clean rooms
- Industrial gas facilities
- Gas storage rooms
- Indoor monitoring
- Iron and steel industry
- Warehouses
- Tunnels and garages
- Vehicle service areas
Specification
Detection | Principle: Galvanic cell Gas: Oxygen (O2) Range: 0 to 25% volume |
Display Resolution | 0.1% volume |
Sampling Method | Diffusion or remote sampling method |
Indication Accuracy | Within ±0.7% volume |
Response Time | 90% response within 30 seconds (T90) |
Alarm Levels | Two preset alarms (L-LL), alarm 1 = 19.5% volume, alarm 2 = 18.0% volume (other settings available) |
Display of Alarm | 1st gas alarm: gas concentration reading blinks, flashing AL 1 icon, orange back light, buzzer 2nd gas alarm: gas concentration reading blinks, flashing AL 2 icon, red back light, buzzer |
Alarm Logic | Latching or non-latching (including trouble alarm) |
Alarm Contact | Dry contact, normally open or normally closed (default setting is normally open) |
Display | Digital LCD (3 digits, 7 segments / Green, Orange, Red) (For Alkaline battery version, the back light will be OFF during normal operation) |
Trouble Alarm / Self-Diagnosis | System trouble / sensor connection trouble |
Display of Trouble Alarm | Buzzer / flashing of red error message |
Relay Contact Rating | 125 V AC, 1 A or 30 V DC, 1 A (resistive load) |
Output Signal | 4 to 20 mA (non-isolated, resistive load under 300?) or 0 to 1 V DC (non-isolated) (Only for 0 to 1 V DC Alkaline battery specification) |
Power Sources | 120 V AC ±10% (50/60 Hz) or 24 V DC ±10% or 2 x AA alkaline batteries |
Power Consumption | AC specification: Maximum 3.5 V A DC specification: Maximum 2 W |
Battery Life | 1 year (no alarm) (Alkaline battery version) |
Approvals | CE marking standard |
Operating Conditions | Temperature: 0 to 104°F (-17 to 40°C) Humidity: 0 to 90% RH (non-condensing) |
Response Time | Within 30 seconds (T90) |
Mounting Equipment | Wall mounting type (by using accessory mounting plate or mount at one switch box) Cable inlet: Up, down and left/right, or rear side |
Dimensions | Body: approximately 3.15 x 4.72 x 1.2" (80 x 120 x 35.5 mm) |
Weight | AC specification: approximately 7.05 oz (approximately 0.2 kg) DC specification: approximately 6.34 oz (approximately 0.18 kg) Alkaline battery specification: approximately 8.11 oz (approximately 0.23 kg) |