RKI 72-PAA-C GX-3R Pro,72-PAA-C 5 gas, LEL / O2 / combo H2S & CO / ppm CO2 with 100-240 VAC charger
$1,380.00
- Brand
- RKI Instruments
- SKU:
- 72-PAA-C
Description
Equipped with Bluetooth wireless communication, this gas monitor can display direct gas readings from the instrument to a phone app and send text or email messages by programming the automatic notifications.
In addition, this monitor flashes its three LED lights every 30 seconds in the following conditions; if this monitor has not been bump tested, if calibration is due, or if there was a gas alarm event. The three LED lights will continue to flash once every 30 seconds until the non-compliance condition has been resolved, and the 30-second interval is adjustable.
Features
- Smallest and lightest gas monitor
- Simultaneous detection of confined space and toxic/IR gases
- Simple two-button operation
- Non-compliance indicator
- Alarms: Audible, visual, and vibration
- Three user adjustable alarm levels
- Panic alarm
- Man down alarm
- Impact resistant body
- Large full dot, auto-backlit display with auto-rotation
- Stealth mode for law enforcement
- Field replaceable sensors and filters
- Water and dust resistant design, IP66/68
Applications
- Personal monitoring
- Confined spaces
- Refineries/petrochemical
- Utilities
- Oil and gas
- Water/wastewater
- Fire services
- Construction
Specification
Gas Detected | |
Carbon Monoxide (CO) | Sensor slot: 1 Detection principle: EC Detection range (increments): 0 to 2000 ppm (1 ppm) Accuracy: ±5% of reading or ±5 ppm CO Preset alarms: A1: 25 ppm A2: 50 ppm A3: 1200 ppm STEL: 200 ppm TWA: 25 ppm |
H2S | Sensor slot: 1 Detection principle: EC Detection range (increments): 0 to 200 ppm (0.1 ppm) Accuracy: ±5% of reading or ±2 ppm H2S Preset alarms: A1: 5 ppm A2: 30 ppm A3: 100 ppm STEL: 5 ppm TWA: 1 ppm |
Combustible Gases (Methane as Standard) | Sensor slot: 2 Detection principle: Catalytic combustion Detection range (increments): 0 to 100% LEL (1% LEL) Accuracy: ±5% of reading or ±2% LEL Preset alarms: 1st: 10% LEL 2nd: 25% LEL 3rd: 50% LEL Over: 100% LEL |
General Specifications | |
Display | Full dot LCD with auto-backlight and autorotation |
Sampling Method | Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) |
Alarm Types | Gas alarm: 2 increasing alarms, STEL, TWA, over scale alarm, O2 decreasing/increasing Trouble Alarm: Sensor disconnection, low battery, circuit error, calibration range error, calibration or bump due alarm Man down alarm Panic alarm |
Display of Alarm | Gas alarm: Flashing LED's, continuous buzzer (100 db at 11.8" or 30 cm), flashing gas value, vibration Trouble alarm: Flashing LED's, intermittent buzzer (95 db at 11.8" or 30 cm), display of error message |
Operating Conditions (Continuous Environment) | Temperature: -4 to 122°F (-20 to 50°C) Humidity: 10 to 90% RH, non-condensing |
Operating Conditions (Temporary Environment) | Temperature: -40 to 140°F (-40 to 60°C) Humidity: 0 to 95% RH, non-condensing |
Response Time | Within 30 seconds (T90) |
Power Source | Configuration: 4-gas + EC, 4-gas + IR Li-ion: 25 hours, 16 hours Alkaline: 16 hours, 7 hours |
Case Material | Explosion proof, dust and water resistant to IP66/68 (2 m,1 h) approval Drop height 23' (7 m) |
Bluetooth Communication | BLE: with iOS and Android phone app: RK Link |
Data Logging | User ID Station ID Calibration and bump test history Alarm events and trends |
Safety Design / Approvals | ATEX CSA |
Dimensions | 2.9 x 2.6 x 1.06" (approximately 73 x 65 x 26 mm) |