UEI DL419 AC/DC 1000A TRMS CLAMP METER
$198.01
- Brand
- UEI test instruments
- SKU:
- DL419
- UPC:
- 53533507157
Description
UEi Industrial Clamp Meter DL419 AC/DC 1000A True RMS
The DL419 is ideal for electricians, MRO & Industrial with the ability to measure AC and DC inductive amps, makes testing generators, compressor pump motors and power converters quick and easy. With its large diameter jaw and 1000V / 1000A range the durable DL419 will always be ready for the job.
Includes:
- 2 Silicon Test leads (ATL57)
- 2 Alligator clips (AAC)
- 2 Batteries (AAA)
- Zippered case
- Manual
Functions:
- True RMS
- 1000A AC / DC
- 1000V AC / DC
- Continuity
- Capacitance
- Frequency
- Diode test
Standards:
- cETLus Listed and RoHS
- Conforms to IEC61010-2-032
- Rated: CAT IV 600V, CAT III 1000V
Specification
Altitude | Operating - up to 2000m (6,561 ft.) Storage - 10,000m (32,808 ft.) |
Humidity | 80% max |
Operating Temperature | 32°F to 104°F (0°C to 40°C) at < 75% R.H |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) at < 80% R.H |
Relative Humidity | 0% to 80% at 32°F to 95°F (0°C to 35°C) 0% to 70% at 32°F to 131°F (0°C to 55°C) |
Temperature Coefficient | Nominal 0.1 x (Specified accuracy) / °C (<18°C or >28°C ; <64°F or >82°F) |
Pollution Degree | 2 |
Display | 3-3/4 digits 4000 counts single LCD display with 20 segments bar graph |
Refresh Rate | 3 times/sec |
Overrange | "OL" is displayed |
Polarity | Automatic(no indication for positive polarity) ; Minus(-) sign for negative polarity |
Dimensions | 10.6" x 2.5" x 1.5" |
Weight | 16.8oz |
Calibration | Accurate for one year |
CAT Rating | : CAT IV 600V, CAT III 1000V |
Certifications | ETL & C-ETL Listed IEC61010-2-032 |
Battery Type | 2 x 1.5V AAA or LR03 |
Silicon Test Lead | IEC61010-2-031 |
Accuracy | ± (% of reading + # of least significant digits) |
AC / DC Voltage: < 1000V | |||
DC Voltage Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
400mV | 0.1 mV | ±(0.5%+ 4 digits) | 1000V |
4V | 1mV | ||
40V | 10mV | ||
400V | 100mV | ||
1000V | 1V | ± (0.8% + 10 digits) | |
AC Voltage Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
400mV | 0.1 mV | ± (2.0% + 5 digits) | 1000V RMS |
4V | 1mV | ||
40V | 10mV | ||
400V | 100mV | ||
1000V | 1V | ||
True RMS:45Hzto 400Hz |
Capacitance (MFD) | |||
Range | Resolution | Accuracy | Overload Protection |
40.00nF | 0.01 nF | ±(3.5%+ 6 digits) | 600V RMS |
400.0nF | 0.1nF | ||
4.000uF | 0.001 uF | ||
40.00uF | 0.01 uF | ||
400.0uF | 0.1 uF | ||
2000uF | 1uF |
Diode Test | |||
Range | Open Circuit Voltage | Test Current (Typical) | Overload Protection |
2.0V | < 1.6V DC | 0.25mA | 600V RMS |
Audible Continuity | |||
Overload Protection | Open Circuit Voltage | ||
600V RMS | <0.44V |
AC/DC Amps: < 1000A | |||
DC Amps Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
40A | 0.01A | ±(2.5%+ 15 digits) | 1000V RMS |
400A | 0.1A | ±(1.5%+ 8 digits) | |
1000A | 1A | ±(1.5%+ 8 digits) | |
AC Amps Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
40A | 0.01A | ±(2.9%+ 15 digits) | 1000V RMS |
400A | 0.1A | ±(1.9%+ 8 digits) | |
1000A | 1A | ±(1.9%+ 8 digits) | |
True RMS: 45Hzto 400Hz |
Resistance: < 40M? | |||
Range | Resolution | Accuracy | Overload Protection |
400? | 0.1? | ±(1.0%+ 4 digits) | 600V RMS |
4k? | 1? | ||
40k? | 10? | ||
400k? | 100? | ||
4M? | 1k? | ||
40M? | 10k? | ± (2.0% + 4 digits) |
AC/DC Low Amps: < 2000µA | |||
DC Low Amps Measurement -Test lead input | |||
Range | Resolution | Accuracy | Overload Protection |
400µA | 0.1µA | ±(1.2%+ 3 digits) | 2000µA/600V RMS |
2000µA | 1µA | ||
AC Low Amps Measurement -Test lead input | |||
Range | Resolution | Accuracy | Overload Protection |
400µA | 0.1µA | ± (2.0% + 5 digits) | 2000µA/600V RMS |
2000µA | 1µA | ±(1.5%+ 5 digits) | |
True RMS: 45Hz to 400Hz (Crest factor < 3:1 ) |