UEI DL479 AC600A TRMS HVAC/R CLAMP METER, SINGLE DISPLAY
MSRP:
$120.95
Now:
$117.90
Was:
$162.95
(You save
$3.05
)
- Brand
- UEI test instruments
- SKU:
- DL479
- UPC:
- 53533507447
- Availability:
- DISCONTINUED, REPLCACED WITH DL579
Description
AC 600A True RMS HVAC/R Clamp Meter
Includes:
- Test leads, w/alligator clips
- Thermocouple temperature probe
- Zippered pouch
- Batteries 2 (AAA)
- Manual
Functions:
- True RMS
- 600A AC
- 750V AC/600V DC
- Resistance 60M?
- Capacitance 2000µF
- Temperature 14° to 752°F (-10° to 400°C)
- DC microamps 2000µA
- Frequency/Duty cycle
- Diode test
- Non-contact voltage detection
- Audible continuity
- 2-Year limited warranty
Applications:
- Motor or line current
- Control voltage or system board voltage checks
- Circuit continuity or specified resistance
- Flame safe guard
- Quick check of live wires
- Diode malfunctions/unbroken paths
Specification
| AC Amps - Jaw Input | ||
| Range | 60A / 600A | |
| Resolution | 0.01A / 0.1A | |
| Accuracy | ±(2.0% +8 dgts) | |
| Overload Protection | 600V RMS | |
| True RMS Frequency Range | Sine 50Hz to 400Hz | |
| Frequency width: 60Hz to 400Hz | 5% to 95% | |
| Frequency width: 400Hz to 4kHz | 15% to 85% | |
| AC Volts (45Hz to 400Hz) | ||
| Range | 600mV / 6V / 60V / 600V / 750V | |
| Resolution | 0.1mV / 1mV / 10mV / 100mV / 1.0V | |
| Accuracy | ±(1.0% +3 dgts) | |
| Overload Protection | 1000V RMS | |
| True RMS Frequency range | Sine 50Hz to 400Hz, Sine 50Hz to 400Hz | |
| Bandwidth | Sine = 0.5% error at 1.5kHz (max) | |
| Bandwidth | Square= 0.5% error at 0.1kHz (max) | |
| Bandwidth | Triangle = 0.5% error at 1.2kHz (max) | |
| DC Volts | ||
| Range | 600mV / 6V / 60V / 600V | |
| Resolution | 0.1mV / 1mV / 10mV / 100mV | |
| Accuracy | ±(0.5% +4 dgts) | |
| Overload Protection | 1000V RMS | |
| DC Low Amps | ||
| Range | 600µA / 2000µA | |
| Resolution | 0.1µA / 1.0µA | |
| Accuracy | ±(1.2% +3 dgts) | |
| Overload Protection | 2000µA/600V RMS | |
| Resistance | ||
| Range | Resolution | Accuracy |
| 600? | 0.1? | ±(0.8% +3 dgts) |
| 6k? | 1? | |
| 60k? | 10? | |
| 600k? | 100? | |
| 6M? | 0.001M? | |
| 60M? | 0.01M? | ±(1.2% +3 dgts) |
| Overload Protection | 600V RMS | |
| Frequency | ||
| Range | Resolution | Accuracy |
| 99.99Hz | 0.01Hz | ±(0.1% per+3 dgts) |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 0.001kHz | |
| Overload Protection | 600V RMS | |
| Duty Cycle | ||
| Range | 0.5% to 95% 60Hz to 400Hz / 15% to 85% 400Hz to 2kHz | |
| Resolution | 0.1% | |
| Accuracy | ±(0.2% per kHz +2.0% +2 dgts) | |
| Overload Protection | 600V RMS | |
| Sensitivity > 6Vpp RMS | ||
| Diode Test | ||
| Range | 4.0V | |
| Open Circuit V | <3.0V DC | |
| Test Current | 1.30mA | |
| Overload Protection | 600V RMS | |
| Capacitance | ||
| Range | Resolution | |
| 60nF | 0.01nF | |
| 600nF | 0.1nF | |
| 6.000µF | 0.001µF | |
| 60.00µF | 0.01µF | |
| 600.0µF | 0.1µF | |
| 2000µF | 1µF | |
| Accuracy | ±(3.0% +5 dgts) | |
| Overload Protection | 600V RMS | |
| Continuity | ||
| Open Circuit V | <1.0V | |
| Response Time | <50ms | |
| Overload Protection | 1000V | |
| Temperature | ||
| Range | 14° to 752°F / -10° to 400°C | |
| Resolution | 0.1°F / 0.1°C | |
| Accuracy | ±(1.5% +3.6°F) / ±(1.5% +2.0°C) | |
| Overload Protection | 600V RMS | |
| Stated accuracy does not account for themocople accuaracy Sensitivity >2Vpp RMS | ||
| Non-Contact Voltage | ||
| On Voltage | ||
| Approx. 25V AC | ||