UEi C161KIT Residential Combustion Analyzer Kit w/ Printer/Cas
$1,003.15
- Brand
- UEI test instruments
- SKU:
- C161KIT
- UPC:
- 53533509236
- Availability:
- In Stock
Description
UEi, C161KIT, Residential Combustion Analyzer Kit with K-Type Probe and Printer
C161KIT Includes Only:
- Residential Combustion Analyzer
- K-type Temp Probes
- Rechargeable batteries 3 (AA)
- USB Charging cable (WIR00067)
- Quick Start Guide (201996)
- Carrying Case
- Infrared printer IRP-2
- Printer paper roll
- Charger AACA5
- Water trap
Features:
- Eligible for UEi Service+
- Large 6-line backlit display
- Heat Exchanger test
- 2 levels of sensor protection
- NOx filtered CO sensor
- Low Flow Detection
- High altitude compensation
- Temperature Differential with K-Type probe inputs
- Protective water trap
- Print to printer
- 8 pre-programmed fuels
- Protective rubber boot with magnet
- DMM-style rotary dial
Functions:
- Measures: CO, CO2, Flue Temperature, Inlet Temperature
- Calculates: O2, Differential Temperature, Efficiency (Net, Gross), Excess Air
The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and now adds a heat exchanger test. Essential information for installing and maintaining furnaces and boilers all in one device.
Specification
| Temperature Measurement | |
| Flue Temperature Range | 32° to 1112°F (0° to 600°C) |
| Flue Temperature Resolution | 1°F/C |
| Flue Temperature Accuracy | ±(0.3% rdg +3.6°F (2°C)) |
| Inlet Temperature (Internal Sensor) Accuracy | ±2°F (1°C) |
| Inlet Temperature (External Sensor) Accuracy | ±1.0°F (0.5°C) |
| Flue Gas Measurement | |
| Carbon Monoxide Range | 0 to 2000 ppm |
| Carbon Monoxide Resolution | 1 ppm |
| Carbon Monoxide Accuracy | ±3 ppm or ±5% rdg (whichever is greater) |
| (Optional H2 Compensated) Range | 2000 to 10000 ppm |
| (Optional H2 Compensated) Resolution | 1ppm |
| (Optional H2 Compensated) Accuracy | ±10% rdg |
| Carbon Dioxide Range | 0 to 20% |
| Carbon Dioxide Resolution | 0.1% |
| Carbon Dioxide Accuracy | ±0.3% volume |
| Calculations | |
| Oxygen Range | 0 to 21% |
| Oxygen Resolution | 0.1% |
| Oxygen Accuracy | ±0.3% volume |
| Efficiency Range | 0 to 99.9% |
| Efficiency Resolution | 0.10% |
| Efficiency Accuracy | ±1.0% rdg |
| Excess Air Range | 0 to 119.9% |
| Excess Air Resolution | 0.10% |
| Excess Air Accuracy | ±0.2% rdg |
| Pre Programmed Fuels | Natural Gas, Propane, LPG, Light Oil, Heavy Oil, Bio Oil, Pellets |
| Battery Life | >8 hours (continuous with pump on) |
| Operating Conditions | |
| Temperature | 32 to 113°F (0 to 45°C) |
| Humidity | 15 to 90% R.H. (non-condensing) |
| Power Supply | Rechargeable Batteries, USB charging |
| Certification | The C163 is TUV-tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BimSchV) |
| CE Conformity | Yes |
| RoHS | EC62321-2:2013, IEC62321-1:2013, IEC62321-3-1:2013, IEC62321-5:2013, IEC62321-4:2013, IEC62321-7-2:2017, IEC62321-7-1:2015, IEC62321-6:2015 |
| REACH Compliant | Yes |
| AHRI 1260 Standard | Yes |
| Certification | The C161 is independently tested and certified to EN 50379, Parts 1-3 in accordance to 1st German Federal Emission Control Ordinance (BlmSchV) |
| EMC | EN50270:2015 |
| Safety | EN61010-1:2010 |