UEI UTL261 UTL DIGITAL CLAMP-ON METER
$39.91
- Brand
- UEI test instruments
- SKU:
- UTL261
- UPC:
- 53533507126
- Availability:
- In Stock
Description
UEi Digital Clamp Multimeter UTL261 UTL
Includes:
- Soft Carrying Case
- Test Leads
- 3 X 1.5V AAA Batteries
- Manual
Features:
- Data Hold
- Auto / Manual Ranging
- Backlit Display
- Max Capture
- Worklight
- 1 Year Limited Warranty
Tests:
- AC Current
- AC/DC Voltage
- Resistance
- Continuity
- Diode Test
- Non-Contact Voltage
Specification
General | |
Display | LCD 3-1/2 Digits 2000 count |
Refresh Rate | 3 times/sec |
Overrange display | "OL" |
Power battery | DC1.5V x 3 SIZE AAA |
Battery Life | Approx. 100 hours |
Clamp jaw opening | 1.02" |
Operating Elevation | Up to 6571.7 ft. (2000m) |
Operating Temperature | 32°F to 104°F (0°C to 40°C) at < 75% R.H |
Storage Temperature | 14°F to 140°F (-10°C to 60°C) at < 80% R.H |
Accuracy Temperature | Stated Accuracy at 73°F ± 41°F (23°C to ± 5°C) < 75% R.H |
Dimensions | 8.66 x 3.19 x 1.6 |
Weight | about 0.63lbs. (286g) (battery installed) |
Certifications | CE, C-ETL-US |
Standards | IEC61010-1, IEC61010-2-032, Double Insulated |
Operating Category | 600V CAT III |
Pollution degree | 2 |
DC Voltage Measurement | |
Range | Resolution / Accuracy |
200mV | 0.1mV / ± (0.6% + 3 dgts) |
2V | 1mV / ± (0.6% + 3 dgts) |
20V | 10mV / ± (0.6% + 3 dgts) |
200V | 0.1V / ± (0.6% + 3 dgts) |
600V | 100mV / ± (0.8% + 3 dgts) |
Input impedance | 10M? |
Overload protection | 600V RMS |
AC Voltage Measurement | |
Range | Resolution / Accuracy |
200mV | 0.1mV / ± (2% + 3 dgts) |
2V | 1mV / ± (0.8% + 5 dgts) |
20V | 10mV / ± (0.8% + 5 dgts) |
200V | 0.1V / ± (0.8% + 5 dgts) |
600V | 100mV / ± (1% + 5 dgts) |
Input impedance | 10M? |
Overload protection | 600V RMS |
Frequency Range | 50Hz to 60Hz |
Diode Test | |
Range | 0.5 - 2.7V |
Max. Test Current | 1mA |
Open Circuit Voltage | 1.5V |
Overload protection | 250V RMS |
AC Current | |
Range | Resolution / Accuracy |
2A | 0.001A / ± (2.0% + 5 dgts) |
20A | 0.01A / ± (2.0% + 5 dgts) |
200A | 0.1A / ± (2.0% + 5 dgts) |
600mA | 1A / ± (2.0% + 5 dgts) |
Frequency Range | 50Hz to 60Hz |
Overload protection | 600A for 20 seconds |
Resistance | |
Range | Resolution / Accuracy |
200? | 0.1? / ± (0.8% + 4 dgts) |
2k? | 0.001k? / ± (0.8% + 4 dgts) |
20k? | 0.01k? / ± (0.8% + 4 dgts) |
200k? | 0.1k? / ± (0.8% + 4 dgts) |
2M? | 0.001M? / ± (0.8% + 4 dgts) |
20M? | 0.01M? / ± (1.2% + 5 dgts) |
Overload protection | 250V RMS |
Continuity | |
Audible Threshold | ? 60? |
Open Test Circuit | 0.45V |
Resolution | 100m? |
Overload protection | 250V RMS |