Winters, LIS395, LIS 0/3,600 PSI Intrinsically Safe Pressure Transmitter
Features:
- Approved for intrinsically-safe applications in Class 1/Div. 1 hazardous areas
- Rugged stainless steel construction with ceramic sensor
- Available ranges include in/Hg up to 8,700 PSI
- Wide range of mechanical and electrical connections
- ±0.5% FSO accuracy
- NEMA 4x and 6P / IP65, IP67 and IP68
- Approved for outdoor use
- Customizable
- 1 year warranty
Applications:
- Appropriate for all hazardous areas where an intrinsically safe rating is required, including oil & gas and chemical installations
| Range | 0/3,600 PSI |
| Over-pressure | 5,802 PSI |
| Burst Pressure | 7,252 PSI |
| Output Signal | Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc I.S. protection: Vs = 14-28 Vdc Optional 3-wire: 0-20 mA / Vs = 14-30 Vdc 0-10 V / Vs = 14-30 Vdc |
| Accuracy | ±0.5% FSO IEC 607770 |
| Permissible Load | Current 2-wire: Rmax = [(Vs - Vs min) / 0.02] Ohm Current 3-wire: Rmax = 500 Ohm Voltage 3-wire: Rmin = 10 kOhm |
| Influence Effects | Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
| Response Time | ?10 ms |
| Thermal Error | ?±0.2% FSO / 10K In compensated range: -13°F to 185°F (-25°C to 85°C) |
| Permissible Temperatures | Medium: -40°F to 257°F (-40°C to 125°C) Electronics environment: -13°F to 185°F (-25°C to 85°C) Storage: -40°F to 212°F (-40°C to 100°C) |
| Short-circuit Protection | Permanent |
| Reverse Polarity Protection | No damage. No function. |
| Electromagnetic Protection | Emission and immunity according to EN 61326 |
| I.S. Protection | Class 1, Div. 1, Groups A, B, C & D |
| Stability | Vibration: 10 g RMS (20 to 2,000 Hz) Shock: 100 g / 1 ms |
| Pollution Degree | 4, electrical equipment for outdoor use |
| Housing | 316L SS |
| Pressure Port | 316L SS |
| Wetted Parts | Seals: PN< 1450 psi: FKM70. Others available. PN> 1450 psi: FKM90. Others available. Diaphragm: Ceramic AI2O396% |
| Weight | 140 g |
| Current Consumption | Current: 25 mA max Voltage: 7 mA max |
| Operating Life | >100 x 106 cycles |
| Connecting Cables | Cable capacitance: Signal line/shield and signal line/ signal line: 160 pF/m Cable inductance: Signal line/shield and signal line/ signal line: 1 µH/m |