AEMC 8336 PowerPad III Power Quality Analyzer with MN193 Current Probes
$5,650.00
- Brand
- Aemc
- SKU:
- 2136.3
- UPC:
- 6.85E+11
- Availability:
- Discontinued
AEMC PowerPad® III Model 8336 is a true RMS power quality analyzer with single, two and three-phase measurements at 256 samples/cycle, plus DC. Unit features four voltage and three current input terminals.
DESCRIPTION
Features:
- True RMS single, two and three-phase measurements at 256 samples/cycle, plus DC
- Four voltage and three current input terminals
- True RMS voltage and current measurement
- Measures DC voltage, current and power
- Real-time colour waveforms
- Displays and captures voltage, current and power harmonics to 50th order, including direction in real-time
- Captures up to 51 transients down to 1/256th of a cycle (65/sec)
- Real-time display of Phasor diagrams with values and phase angles
- Peak voltage and current
- Nominal frequency from 40 to 70Hz
- VA, VAR and W per phase and total
- kVAh, VARh and kWh per phase and total
- Neutral current display for three-phase
- Calculation of crest factors for V and A
- Calculation of K Factor for transformers
- Calculation of Power Factor (PF) and displacement PF
- Captures up to 51 transients
- Short-term flicker display
- Phase unbalance (voltage and current)
- Displays harmonic sequencing and direction and calculation of overall harmonics
- Alarms, surges and sags
- Records, times stamps and characterizes disturbances
- Screen snapshot function captures waveforms or other information on display
- 2GB of memory for trend recordings
- Separate memory for up to 12 snapshots and 4000 alarm events
- Colour 1/4 VGA TFT screen (320 x 240) diagonal, 148mm
- Optically isolated USB communication port
- Cat. 1000V, Cat. IV 600V safety rated
- Five voltage and four current input terminals
- Measurement of TRMS AC/DC voltages for two-, three-, four- or five-wire systems
- Up to 210 transient detection on all V and I inputs down to 65/sec
- Selectable PT and CT ratios
- Inrush current measurement
- Calculation of short-term and long-term flicker
- Harmonic measurements (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic
- Monitors the average value of any parameter, calculated for a period from 1 sec to 2 hrs
- Measurement of active, reactive and apparent power per phase and their respective sum total
- Calculation of tangent factor
- 2GB card for Trend Recording memory and 4MB partitioned for Alarm (10,000 events), Snapshot (up to 50 snapshots) and Transient (up to 210)
- Max and Min RMS measurements are calculated every half period
Applications:
- Energy audits and voltage investigations
- Load studies
- Power factor studies
- Flicker and imbalance
SPECIFICATION
Input Terminals | 5 voltage/4 current |
Inputs | 4 voltage/4 current |
Voltage Range | Phase-to-Phase: 0 to 2000V Phase-to-Neutral: 0 to 1000V |
Voltage Ratio | up to 500kV |
Frequency | 40 to 70Hz |
Distribution Systems | 1P-2W, 1P-3W, 2P-2W, 2P-3W, 2P-4W, 3P-3W,3P-4W, 3P-5W, Split-phase 2W & 3W, 2-1/2 Element, Aron meters |
Power Values | W, VA, VAR, VAD, PF, DPF, cosine, tangent |
Energy Values | Wh, VARh, VAh, VADh |
Harmonics | 1st to 50th , Direction, Sequence; THD: 0 to 50, Phase |
Transients | up to 210 |
Flicker | Pst & Plt |
Trend Mode | Records up to 41 variables as fast as once per second for one month |
Alarm Mode | 40 types; 10,000 recorded |
Snapshot Mode | 50 |