AEMC SR651 Description:
This general purpose 1000AAC current probe is designed for use with DMMs, loggers and other instruments that have voltage inputs. It has a voltage output proportional to the rate of 1mV per amp to the current measured in the jaw. The SR651 has jack output terminations that accept 4mm banana plugs. The rounded jaw design on this probe makes it well-suited for power applications where high accuracy and low phase shift are important.
Features
- Measurement range of 100mA to 1200AAC
- Large jaw opening accommodates conductors up to two 500kcmil
- Improved ergonomic design and easy operation
- Conforms to EN 61010, 600V CAT III
- Low phase shift for power measurement
- Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
Applications
- Power quality measuring
- Large industrial loads
- Measuring around cable bundles
- Power load monitoring
- Waveform analysis
AEMC SR651 Specifications:
Nominal Range | 1000A |
Measurement Range | 0.1 to 1200A |
Transformation Ratio | Voltage output |
Output Signal | 1mV/A AC/A AC (1V AC at 1000A) |
Accuracy (1000A Range) | 1 to 50A: ?3% ± 0.1A 50 to 200A: 1.5% of Reading 200 to 1000A: 0.75% of Reading 1000 to 1200A: 0.5% of Reading |
Phase Shift (1000A Range) | 50 to 200A: 1.5° 200 to 1000A: 0.75° 1000 to 1200A: 0.5° |
Overload | 1200A for 40 min ON, 20 min OFF |
Frequency Range | 30Hz to 5kHz Current derating above 1kHz using the formula: 1000A x 1/F (in kHz) |
Load Impedance | 100k? min |
Working/Common Mode Voltage | 600V Cat. III |
Output Termination | Jack |
What's included with the AEMC Instruments SR651
- AC Current Probe
- User Manual