AEMC Multi-Function Installation Tester Model C.A 6117
$3,175.00
- Brand
- Aemc
- SKU:
- 2138.07
- UPC:
- 6.85338E+11
AEMC Multi-Function Installation Tester Model C.A 6117 The High performance C.A6117 offers excellent measurement stability, even in electrically noisy industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, ground resistance, selective earth measurements, loop impedance and type A and AC RCDs (GFCI circuits). The 6117 can also be used to measure voltage, frequency, AC current (via a current clamp), active power, harmonics and phase rotation. The C.A6117 is also equipped with type B RCD testing, a built in fuse table and a voltage drop feature. CONTINUITY / RESISTANCE I Rated / Range / Resolution I > 200mA / 39.99é/ 0.01é / ± (1.5% of R + 2cts)12mA / 39.99é & 399.9é / 0.01 & 0.1é /± (1.5% of R + 5cts) with beep Range / Resolution / Accuracy 4 ké/ 1é / ±(1.5% of R + 5cts) 40 ké - 400ké/ 10é - 100é / ±(1.5% of R + 2cts) INSULATION Rated Voltage Utest: 50 /100 / 250 / 500 / 1000VDC Range / Resolution / Accuracy 0.01Mé to 2Gé / 10ké to 1Mé / ±(5% of R + 3cts) Short Circuit Current ¤ 3mA GROUND 3P GROUNDRange / Resolution / Accuracy 0.50 to 40é/ 0.01é / ±(2% of R + 10cts) 40é to 15ké / 0.1 to 1é / ±(2% of R + 2cts)15 to 40ké / 10é/ ±(10% of R + 2cts) Others Measurement of resistance of auxiliary stakes RH & RS (up to 40ké) Ufk Complies with SEV 3569 1P SELECTIVE GROUNDRange / Resolution / Accuracy 0.20 to 39.99é - 40 to 399.9é / 0.01 to 0.1é / ±(10% of R + 10cts) (ISel via clamp) LOOP IMPEDANCE (Zs (L-PE0 AND Zi (L-N OR L-L) 1P LIVE GROUND Live GroundInstallation Voltage / Frequency 90 to 500 V / 15.8 to 17.5Hz - 45 to 65Hz High-current mode with TRIPZs (L- PE) & Zi (L- N or L - L)Range / Resolution / Accuracy Max. test current: 7.5 A(0.050) 0.100 to 0.5é / 0.001é/ ±(10% of R + 20cts) ¢ 0.5é to 3.999é / 0.001é/ ±(5% of R + 20cts) 3.999 to 39.99é/ 0.01é / ±(5% of R + 2cts) ¢ 39.99 to 399.99é / 0.1é/ ±(5% of R + 2cts) NO TRIP mode (Zs (L PE) 0nly) Test current 6mA 9mA 12mA (as required) 0.20 to 0.99é / 0.01é / ±(15% of R + 10cts) 1.00 to 1.99é / 0.01é / ± (15% of R + 3cts) 2.00 to 39.99 / 0.01é / ± (10% of R + 3cts) 40.00 to 399.9é / 0.1é ± (5% of R + 2cts) 400 to 3999é / 1é ±(5% of R + 2cts) Calculation of IK short circuit current (PFC (Zs), I Sc PSCC (Zi) Fault current and short-circuit current: 0.1 to20kA Integrated Fuse Table Yes Voltage drop V%(Zi) -40% to +40% Others Measurement of the resistive and inductive components of Zs and Zi impedances AC and type RCDs Installation voltage / Frequency 90 to 500V / 15.8 to 17.5Hz and 45 to 65Hz IÃn 10/30/100/500/650/1,000 (90V - 280V) or variable ramp and pulse test N-trip test At ½ IÃn Duration 1000ms or 2000ms Ramp mode 0.2 to 0.5 x IÃn(Uf) / 0.3 x IÃn to 1.06 IÃn increments of 3.3% x IÃn Trip test: R:Range / Resolution / Accuracy 0.2 to 0.5 x IÃn(Uf) / 0.5 x IÃn / 2 x IÃn(selective) / 5 x IÃnPulse: 0 to 500ms/0.1 and 1ms / 2ms, Ramp mode: 0 to 200 ms / 0.1 ms / 2 ms B-Type RCDs Installation Voltage / Frequency 90 to 275V / 15.8 to 17.5Hz and 45 to 65Hz IÃn: ramp / pulse 2 x IÃnpulse 4 x IÃn 10/30/100/500mA10/30/100/500 mA with pulse 4 IÃnDuration: 150 ms with 4 x IÃn or 300 ms with 2 x IÃn Test in ramp mode 0.2 x IÃn to 2.2 x IÃn Trip test: 2 x IÃn4 x IÃn IÃn ¤ 200 mA: 2.2 x 2 x IÃnIÃn ¤ 200 mA: 1.1 x 2 x IÃnIÃn ¤ 100 mA: 2.2 x 4 x IÃn OTHER MEASUREMENTS Current by Current Probe C177A 5.0mA t0 199.9A Current by Current Probe MN77 (1mA*) 5.0mA to 19.99A Voltage 0 to 550VAC/DC / DC and 158 to 500Hz Frequency 10 to 500Hz Phase rotation 20 to 500VAC Active power 0 to 110kW single phase 0 to 330kW three-phaseSimultaneous display of voltage and current waveforms Harmonics Voltage and Current / up to 50th order / THD-F / THD-R GENERAL SPECIFICATIONS Display Large 5.7 backlit graphic color LCD 320 x 240 pixels Storage/Communication USB for data transfer to Dataview software (Included) Power Supply Rechargeable battery Lithium-Ion 10.8V, 5.8Ah Battery Life Up to 30 hours Protection IP 53 / IK04 Dimension / Weight 11 x 7.48 x 5.04 (280 x190 x 128mm) 4.85 lbs (2.2 kg) EMC IEC61326-1 Safety IEC61010-1 600V CAT III 300V CAT IV IEC 61557