Megger MFT70 Offers
Features
- Simple color-coded test selection and large clear backlit display for ease of use
- Internal memory and Bluetooth® communications
- 3-terminal ground test and stakeless testing for spike resistance measurement
- GFCI testing as defined in the ANSI/UL 943, CSA C22.2 No. 144.1 and ANCE NMX-J-520
- IEC61010 CATIV safety ratings and tough IP54 case
- Altitude 2000 m to full safety specification
- Scratch resistant backlit display
- Adjustable auto switch off
- Small and lightweight
- Ambidextrous - Left or right handed operation
- Terminal shutters aid connection
- Connection label always visible
- Dual function display with analogue arc
- Features internally rechargeable batteries with a charge time of less than 4 hours
Insulation Test | |
---|---|
Output Voltage | -0% +20% at rated load or less |
Voltage Display | ±3% ±3 digits ±0.5% of rated voltage |
Short Circuit Current | 1.5 mA nominal test current |
Test Current on Load | 1 mA at min pass values of insulation |
Resistance and Continuity | |
Intrinsic Accuracy | ±2% ±2 digits (0.01 to 99.9 Ω) ±5% ±2 digits (100 Ω to 99.9 kΩ) |
Open Circuit Voltage | 5 V ±1 V |
Test Current | (0 to 2 Ω) 205 mA ±5 mA 15 mA ±5 mA (user selectable) |
GFCI Test | |
Intrinsic Current Accuracy | Ramp test current: ±5% ±1 digit Supply: 48 to 280 V, 45 to 65 Hz Max service error: ±10% ±2 digits |
Ground Test | |
Resolution | 0.01 Ω |
Current | 0.45 or 4.5 mA |
Max Probe Resistances | Rp and Rc 100 kΩ at 50 V 5 kΩ at 25 V |
Two and Three Pole Method | (0.01 Ω to 1.999 kΩ) ±2.0% ±3 digits |
Functionality
The multifunction tester is designed for testing low voltage electrical installations to fulfill the requirements of NFPA70 and the National Electrical Code. It provides all the tests required to complete the necessary electrical certification for industrial, commercial and domestic fixed wiring installations, including:
- System voltage and frequency measurement (TRMS)
- Insulation test at 100 V, 250 V, 500 V and 1000 V
- Input protection against live circuits up to 600 V even when insulation test is locked-on
- Continuity resistance at 200 mA or 15 mA
- Automatic – no need to press TEST which leaves both hands free to hold probes
- Resistance range up to 100 kΩ
- Fast continuity buzzer and selectable thresholds
- GFCI test
- Ramp test displays trip current
- Ground testing
- 2-pole
- 3-pole
- Attached Rod Technique (ART)*
- Stakeless techniques
Easy to use
The unique modern styling allows it to be operated while standing on the floor, a ladder-shelf or platform, hung around the neck or handheld. Dual TEST and LOCK buttons – one pair at each end – make the tester easy to operate with either the left or right hand.
Easy to pick up and use, the rotary controls are color coded to make range selection fast, along with reducing the chance of using the wrong function or range. Features a large crystal clear backlit display with no hidden menus or complicated screens that uses an innovative digital/analog arc, providing an indication of fluctuating readings. The dual digital readout shows precise values of key measurements and the test parameters simultaneously, such as the output voltage on insulation testing as well as the resistance value in MΩ.
Supplied with NiMH rechargeable cells which can be recharged in the instrument using the provided universal charger. In the event of a flat battery and no facility to charge the tester can also operate from AA Alkaline cells.
Storage and communications
The tester includes built-in memory and Bluetooth® communications that allows you to download memory using the Megger Download Manager (supplied) for simple form filling of test results. The built-in memory also allows results to be stored on the go and transferred to a Bluetooth® enabled device for full traceability.
Safety
This instrument is IEC 61010 CAT IV 300 V rated for connection to low voltage systems with no protective device, so it is safe for connection anywhere on the system up to the source transformer without risk of damage from large transient spikes.
Designed for tough environments and ultimate reliability, this unit features a rubber over mold for extra protection and grip with IP54 protection against dust and water, as well as class leading input protection which ensures it can withstand accidental misuse and voltage transients.
Includes full input protection and safety warnings when a hazardous voltage is present. If live voltages exist on a circuit during insulation or continuity testing, the voltage is displayed on the screen. If this voltage exceeds a safe level, further testing is inhibited and a warning beep sounds.
Applications
- Ground rod testing
- Electrical installations (domestic, commercial and industrial)
- Equipment installation
- Commissioning
- Signage
- Lighting installation
- Testing and certification
- Facilities maintenance
- Lightning protection
- Micro-generation installation and commissioning
- Solar
- Maintenance