Megger BD-59092 MOM2 with Kelvin clamps 3 m and MOM2 Win
- Brand
- Megger
- SKU:
- BD-59092
- Availability:
- In Stock
Features
- Up to 240 A
- Bluetooth? headset for audible pass/fail testing against adjustable limits
- Battery powered
- Handheld, lightweight, weighing only 2.2 lbs (1 kg)
- Safe test - DualGround?
- Auto range from 1 microohm to 1000 milliohms
- Ultra capacitor technology (patent pending)
Applications
- Circuit breaking testing
- Testing of bus-bar
- Switches
- Disconnecting devices
- Safety ground connections
- Welding points
- Fuses
- Cables
Both Sides Grounded
Within electrical power utilities, switchgear owners and service companies, there is an increased emphasis on efficiency of operations, maintenance and service levels. There is an increased emphasis on health, safety, and environmental compliance. Experience has also shown demands for shorter time periods for testing, while the switchgear is less and less available to be taken out of service.
Many utilities require safety grounds to remain in place during station outages, therefore, the MOM2 was designed with this field safety constraint in mind. DualGround means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow. Minimum time shall be spent in the substation and focus shall be on the test rather than the equipment.
Instrument Front View
- 1. Current output terminal (-)
- 2. Current output terminal (+)
- 3. Display
- 4. Ground (earth) terminal
- 5. Keys for navigation and to make settings in the display
- 6. TEST-button
- 7. Stand-by/Wake up (Press shortly to toggle)
- 8. Clear log (Press and hold for 5 seconds)
- 9. Function selector
- 10. Connector for the voltage (?) sense lead
- 11. Connector for the voltage sense (+) lead and the trig function
- 12. Connector for the battery charger
- 13. Battery charger indicator
The Kelvin probes (included in BD-59090) are used for a 4-wire Kelvin test. This is a way of measuring continuity resistances ensuring all contact and lead resistances are compensated for, allowing a much greater accuracy in measurements. Each Kelvin probe assembly has two probe tips: one tip is for the current generated; the other will measure the very small voltage present.
The Kelvin clamps (included in BD-59092) use the same principle.
Equipment and methods that supports DualGround? testing are associated with the DualGround symbol. This symbol certifies the use of groundbreaking technology and methods that enables a safe, fast and easy work?ow with both sides grounded throughout the test.??
Megger BD-59092 Specifications
Application Field | For use in high-voltage substations and industrial environments. |
Relative Humidity %RH | 5%-95%, non condensing |
Pollution Degree | 2 |
Shock | IEC 60068-2-27 |
Vibration | Vibration IEC 60068-2-6 |
Transport | ISTA 2A |
Battery Power | Five AA (HR6) 2700 mAh NiMH cells |
Recharge Time | < 12 h |
Battery Charger Mains Voltage | 100 - 250 V AC, 50 / 60 Hz |
Power Consumption | 60 W |
Protection | Against wrong battery type, low/high temperature |
Real Time Clock Battery Life | =10 years |
Audible Feedback | Different buzzer sounds |
User Presets | 3 |
Field Calibration | Yes |
Encapsulation | IP54 |
Dimensions | 217 H x 92 B x 72 D mm |
Weight | 1.0 kg (2.2 lbs) instrument only |
What's included with the Megger BD-59092
- MOM2 Micro-Ohmmeter
- 4 ft. (1.3 m) Test Cables with Kelvin Probes (including one with trig button) (2)
- Transport Case
- Charger
- Rubber Holster
- Carrying Strap
- Belt Clip
- MOM2 Win Software