RKI 81-SDM6000 SDM-6000 calibration station for GX-6000 with particle filter, connection brackets, & 10 exhaust tube (no AC adapter)
- Brand
- RKI Instruments
- SKU:
- 81-SDM6000
Description
Intended for use with the GX-6000, this docking and calibration station accepts GX-6000 with or without rubber boot.
Features
- Charge, calibrate, bump test, and alarm test
- Automatically power instruments on / off for scheduled calibration
- Simultaneously bump / calibrate, charge, and collect data up to 10 instruments
- No tubing, adaptors or wires needed to connect
- One power source for all stations
- Configure GX-6000 parameters
- Centralize instrument data from multiple stations and locations to one network location
- Ethernet port for LAN connectivity
- Schedule automatic calibration / bump test
Stand alone station
This docking and calibration station is a versatile maintenance tool that automates the service of a GX-6000 portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via SD card (PC software and SD card included).
Modular design
These docking and calibration stations are modular by design and can easily connect to each other without the need of any tubes or cables. One power source and one set of calibration equipment can provide service for up to 10 calibration stations.
Up to 10 calibration stations can also be connected to one PC for automated charging, calibration, bump testing and archiving of data. Even if instruments are turned off, automated routines will power up the instruments and run as scheduled. All data collected from the PC Controlled software can also be centralized in one network location accessible by anyone with the PC Controlled software with access to the network location.
Specification
Display | Touch panel TFT liquid crystal: 3.5" (8.9 cm), 320 x 240 image element QVGA, RGB1677 million colors Back light |
LED | 3 colours (green, red, orange) Each status is indicated by Lighting/Blinking |
Bump Test | Standard setting values: AIR flush time (15 seconds), GAS time (20 seconds), AIR purge time (5 seconds) Threshold values: ±50%, auto calibration: OFF, auto alarm function check: ON Auto print: OFF |
Calibration | Standard setting values: AIR flush time (30 seconds), GAS time (90 seconds), AIR purge time (30 seconds) Auto alarm function check: ON Auto print: OFF |
Power (AC Adaptor) | 100 to 240 V AC (50/60 Hz) |
Operating Conditions | Temperature: 0 to 104°F (-17.8 to 40°C) Humidity: < 95% RH (non-condensing) |
USB Printer Port | A type: Connects SDM-6000 printer (SII, DPU-S245) via USB cable |
RJ-45 Connector | Ethernet port for a LAN connection |
SD Card Slot | Compatible with SD and SDHC cards |
Joint Connector | Connecting SDM-6000 (maximum 10 units) and SV-3 |
Inlet | 4 inlets: GAS 1 / GAS 2 / GAS 3 / AIR |
Certification | CE marking |
Dimensions | 5.11 x 13 x 7.2" (0.13 x 0.33 x 0.18 m) |
Weight | Approximately 3.7 lbs (1.68 kg) |