REED Instruments RINDUST-KIT INDUSTRIAL COMBO KIT
- Brand
- REED Instruments
- SKU:
- RINDUST-KIT
Description
RINDUST-KIT, Industrial Combo Kit
This Industrial Combo Kit includes the tools required for your plant maintenance needs. The RINDUST-KIT includes a Multimeter, Clamp Meter, AC Voltage Detector, Infrared Thermometer and Hard Carrying Case. The carrying case features a customized foam insert built specifically to store and protect the included instruments.
Includes: | |
REED R5010 True RMS Waterproof Digital Multimeter True RMS multimeter with built-in non-contact voltage detector and 40,000 count backlit LCD display. | |
REED R5020 AC Clamp Meter Compact AC clamp meter with built-in non-contact voltage detector and contact thermometer. | |
REED R2002 Compact Infrared Thermometer Pocket-sized infrared thermometer with backlit display and fixed emissivity will cover 90% of non-contact temperature applications. | |
REED R5100 Non-Contact AC Voltage Detector with Flashlight Durable double molded plastic housing. | |
REED R1000 Safety Test Lead Set, Double Insulated Right angle and straight end flexible leads with shrouded banana plugs. | |
REED TP-01 Beaded Thermocouple Wire Probe This Type-K beaded thermocouple wire probe is recommended for basic general purpose temperature applications. The TP-01 is color coded according to ANSI thermocouple identification standards. | |
REED R8890 Deluxe Hard Carrying Case, 15.7 x 12.6 x 6.7" Professional grade, injection molded hard plastic case with customizable foam inserts. |
Specification
R5010 Specifications | |
AC/DC Voltage | |
Range | AC: 400mV, 4, 40, 400, 1000VDC: 400mV, 4, 40, 400, 1000V |
Accuracy | AC: 400mV ±(1.0% rdg. + 5 dgt.)4, 40, 400, 1000V ±(1.0% rdg. + 3 dgt.)DC: 400mV/4,40,400V ±(0.06% rdg. + 2 dgt.)1000V ±(0.1% rdg. + 5 dgt.) |
Resolution | AC: 0.1mV, 0.001, 0.01, 1VDC: 0.01mV, 0.0001, 0.01, 0.1V |
AC/DC Current | |
Range | 400, 4000µA, 40, 400mA, 10A |
Accuracy | AC: ±(1.5% rdg. + 3 dgt.)DC: ±(1.0% rdg. + 3 dgt.) |
Resolution | AC: 0.1, 1µA, 0.01,0.1mA, 0.01ADC: 0.01, 0.1µA, 0.001,0.01mA, 0.001A |
Resistance | |
Range | 400?, 4, 40, 400k?, 4, 40M? |
Accuracy | 400?: ±(0.3% rdg. + 9 dgt.)4, 40, 400k?, 4M?: ±(0.3% rdg. + 4 dgt.)40M?: ±(2.0% rdg. + 10 dgt.) |
Resolution | 0.01?, 0.0001, 0.001, 0.01k?, 0.001M? |
Capacitance | |
Range | 40, 400nF, 4, 40, 400, 4000µF, 40mF |
Accuracy | 40, 400nF: ±(3.5% rdg. + 40 dgt.)4, 40, 400µF: ±(3.5% rdg. + 10 dgt.)4000µF, 40mF: ±(5% rdg. + 10 dgt.) |
Resolution | 0.001, 0.01nF, 0.0001, 0.001, 0.01, 0.1µF, 0.001mF |
Frequency | |
Range | 40, 400Hz, 4, 40, 400kHz, 4, 40, 100MHz |
Accuracy | ±(0.1% rdg. + 1 dgt.) |
Resolution | 0.00, 0.01Hz, 0.0001, 0.001, 0.01kHz, 0.0001, 0.001, 0.01MHz |
Temperature | |
Range | -58 to 1832°F (-50 to 1000°C) |
Accuracy | ±(1.0% rdg. + 4.5°F)±(1.0% rdg. + 2.5°C) |
Resolution | 1°F, 1°C |
4-20mA% | |
Range | -25 to 125% |
Accuracy | ±(50 dgt.) |
Resolution | 0.01% |
General Specifications | |
Range Selection | Autoranging/Manual |
True RMS | Yes |
Display | 40,000 count LCD display |
Display Hold | Yes |
Max/Min | Yes |
Peak Hold | Yes |
Relative Mode | Yes |
Diode Test | Yes |
Backlit Display | Yes |
Digital Analog Bargraph | Yes |
Continuity Check | Audible signal if resistance ?35? |
Duty Cycle | Yes (0.1 - 99.9%) |
Kick Stand | Yes |
Auto Power Off | Yes (after 15 minutes) |
Power Supply | 9V Battery |
Low Battery Indicator | Yes |
Fuse Protection | Yes |
Replaceable Test Leads | Yes |
Overvoltage Category | CAT. IV 600V, CAT. III 1000V |
Product Certifications | CE, IP67, Drop Tested (2M) |
Operating Temperature | 41 to 104°F (5 to 40°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Dimensions | 7.4 x 3.2 x 2.0" (187 x 81 x 50mm) |
Weight | 12oz (342g) |
R5020 Specifications | |
AC Current | |
Range | 40, 400A |
Accuracy | AC: ±(2.5% rdg. + 8 dgt.) |
Resolution | 0.01, 0.1A |
AC/DC Voltage | |
Range | AC: 4, 40, 400, 600VDC: 400mV, 4, 40, 400, 600V |
Accuracy | AC: ±(1.8% rdg. + 8 dgt.)DC: ±(1.5% rdg. + 2 dgt.) |
Resolution | AC: 0.001, 0.01, 0.1, 1VDC: 0.1mV, 0.001, 0.01, 0.1, 1V |
Resistance | |
Range | 400?, 4, 40, 400k?, 4, 40M? |
Accuracy | ±(1.5% rdg. + 2 dgt.)0.1?, 0.001, 0.01, 0.1k?, 0.001, 0.01M? |
Capacitance | |
Range | 40, 400nF, 4, 40, 100µF |
Accuracy | ±(3% rdg. + 5 dgt.) |
Resolution | 0.01, 0.1nF, 0.01, 0.1?F |
Frequency | |
Range | 10MHz |
Accuracy | ±(1.2% rdg. + 2 dgt.) |
Resolution | 0.01Hz |
Temperature | |
Range | -4 to 1400°F (-20 to 760°C) |
Accuracy | ±(3.0% rdg. + 9°F)±(3.0% rdg. + 5°C) |
Resolution | 1°F, 1°C |
General Specifications | |
Range Selection | Autoranging / Manual |
Display | 4,000 count LCD display |
Display Hold | Yes |
Relative Mode | Yes |
Diode Test | Yes |
Continuity Check | Audible signal if resistance <150? |
Duty Cycle | Yes |
Non-Contact Voltage Detector | Yes |
Autoshut off | Yes (after 15 mins) |
Power Supply | 2 x AAA |
Low Battery Indicator | Yes |
Jaw Opening | 1.2" (30mm), up to 350 MCM |
Overvoltage Category | CAT. III 600V |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Dimensions | 7.9 x 2.6 x 1.5" (200 x 66 x 37 mm) |
Weight | 7.2oz (205g) |
R2002 Specifications | |
Temperature Range | -58 to 932°F (-50 to 500°C) |
Accuracy | ±2% of reading or 4°F (2°C) |
Resolution | 0.1°F (0.1°C) |
Optical Resolution (D:S) | 8:1 |
Spectral Response | 6 to 14µm |
Emissivity | 0.95 (Fixed) |
Response Time | <1 sec |
Display Size/Type | 1" LCD |
Backlit Display | Yes |
Display Hold | Yes |
Max/Min | Yes |
F/C Switchable | Yes |
Auto Shut Off | Yes (after 8 secs) |
Laser Class | Class II |
Low Battery Indicator | Yes |
Power Supply | 9V battery |
Product Certifications | CE |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Storage Temperature | -4 to 140°F (-20 to 60°C) |
Operating Humidity Range | 10-90% |
Dimensions | 5.2 x 3.2 x 1.4" (131 x 82 x 35mm) |
Weight | 4.6oz (130g) |
R5100 Specifications | |
Voltage Range | 50 to 1000V AC |
Frequency Range | 50 to 60Hz |
Built-in Flashlight | Yes |
Auto Power Off | Yes (after 3 minutes) |
Power Supply | 2 AAA Batteries |
Overvoltage Category | CAT. III 1000V, CAT. IV 600V |
Product Certifications | CE, UL |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Operating Humidity | 0 to 85% |
Storage Temperature | 14 to 122°F (-10 to 50°C) |
Dimensions | 6.3 x 1 x 1" (159 x 25 x 25mm) |
Weight | 1.5oz (42g) |
TP-01 Specifications | |
Measurement range | -40 to 482°F (-40 to 250°C) |
Dimensions | Wire: 38" (96.5cm) |
R1000 Specifications | |
1000V, 10ACAT III. 1000V and CAT IV. 600V | |
Dimensions | Length: 48" (1.2m), Tip: 0.2" (5mm),Probe: 6.1" (155mm) |
R8890 Specifications | |
Dimensions | Internal dimensions: 14.2 x 10.1 x 4.5" (361 x 257 x 114mm)External dimensions: 15.7 x 12.6 x 6.7" (399 x 320 x 170mm)Weight: 6lbs (2.72kg) |